  "document": {
    "acknowledgments": [
      {
        "organization": "CERTVDE",
        "summary": "coordination.",
        "urls": [
          "https://certvde.com/en/"
        ]
      },
      {
        "names": [
          "Jesson Soto Ventura",
          "Matthew Waddell"
        ],
        "organization": "ivision",
        "summary": "reporting."
      }
    ],
    "aggregate_severity": {
      "namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
      "text": "High"
    },
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "tlp": {
        "label": "WHITE",
        "url": "https://www.first.org/tlp/"
      }
    },
    "lang": "en-GB",
    "notes": [
      {
        "category": "summary",
        "text": "Multiple vulnerabilities in the firmware of CHARX SEC-3xxx charging controllers have been discovered.",
        "title": "Summary"
      },
      {
        "category": "description",
        "text": "The vulnerabilities can lead to a total loss of confidentiality, integrity and availability of the devices.",
        "title": "Impact"
      },
      {
        "category": "description",
        "text": "Affected charging controllers are designed and developed for the use in closed industrial networks. Phoenix Contact therefore strongly recommends using the devices exclusively in closed networks and protected by a suitable firewall.",
        "title": "Mitigation"
      },
      {
        "category": "description",
        "text": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality in FW <=1.6.5 and in the meantime there is no vendor fix planned for these issues.",
        "title": "Remediation"
      },
      {
        "category": "general",
        "text": "For general information and recommendations on security measures to protect network-enabled devices, refer to the application note: [Application Note Security](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).",
        "title": "General Recommendation"
      },
      {
        "category": "description",
        "text": "CHARX SEC EVSE charging controller",
        "title": "Product Description"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "psirt@phoenixcontact.com",
      "name": "Phoenix Contact GmbH & Co. KG",
      "namespace": "https://phoenixcontact.com/psirt"
    },
    "references": [
      {
        "category": "external",
        "summary": "PCSA-2025-00001",
        "url": "https://phoenixcontact.com/psirt"
      },
      {
        "category": "external",
        "summary": "Phoenix Contact advisory overview at CERT@VDE",
        "url": "https://certvde.com/de/advisories/vendor/phoenixcontact/"
      },
      {
        "category": "self",
        "summary": "VDE-2025-014: Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers - HTML",
        "url": "https://certvde.com/en/advisories/VDE-2025-014"
      },
      {
        "category": "self",
        "summary": "VDE-2025-014: Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers - CSAF",
        "url": "https://phoenixcontact.csaf-tp.certvde.com/.well-known/csaf/white/2025/vde-2025-014.json"
      },
      {
        "category": "external",
        "summary": "Phoenix Contact application note",
        "url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf"
      }
    ],
    "title": "Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers",
    "tracking": {
      "aliases": [
        "VDE-2025-014",
        "PCSA-2025-00001"
      ],
      "current_release_date": "2025-07-08T10:00:00.000Z",
      "generator": {
        "date": "2025-07-01T07:46:11.590Z",
        "engine": {
          "name": "Secvisogram",
          "version": "2.5.27"
        }
      },
      "id": "VDE-2025-014",
      "initial_release_date": "2025-07-08T10:00:00.000Z",
      "revision_history": [
        {
          "date": "2025-07-08T10:00:00.000Z",
          "number": "1",
          "summary": "Initial Revision"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_name",
                "name": "CHARX SEC-3150",
                "product": {
                  "name": "CHARX SEC-3150",
                  "product_id": "CSAFPID-11001"
                }
              },
              {
                "category": "product_name",
                "name": "CHARX SEC-3100",
                "product": {
                  "name": "CHARX SEC-3150",
                  "product_id": "CSAFPID-11002"
                }
              },
              {
                "category": "product_name",
                "name": "CHARX SEC-3050",
                "product": {
                  "name": "CHARX SEC-3050",
                  "product_id": "CSAFPID-11003"
                }
              },
              {
                "category": "product_name",
                "name": "CHARX SEC-3000",
                "product": {
                  "name": "CHARX SEC-3000",
                  "product_id": "CSAFPID-11004"
                }
              }
            ],
            "category": "product_family",
            "name": "Hardware"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "<FW 1.7.3",
                "product": {
                  "name": "Firmware < FW 1.7.3",
                  "product_id": "CSAFPID-21001"
                }
              },
              {
                "category": "product_version",
                "name": "FW 1.7.3",
                "product": {
                  "name": "Firmware 1.7.3",
                  "product_id": "CSAFPID-22001"
                }
              },
              {
                "category": "product_version_range",
                "name": "<=FW 1.6.5",
                "product": {
                  "name": "Firmware <= FW 1.6.5",
                  "product_id": "CSAFPID-21002"
                }
              }
            ],
            "category": "product_family",
            "name": "Firmware"
          }
        ],
        "category": "vendor",
        "name": "Phoenix Contact"
      }
    ],
    "product_groups": [
      {
        "group_id": "CSAFGID-0001",
        "product_ids": [
          "CSAFPID-31001",
          "CSAFPID-31002",
          "CSAFPID-31003",
          "CSAFPID-31004",
          "CSAFPID-31005",
          "CSAFPID-31006",
          "CSAFPID-31007",
          "CSAFPID-31008"
        ],
        "summary": "Affected products."
      },
      {
        "group_id": "CSAFGID-0002",
        "product_ids": [
          "CSAFPID-32001",
          "CSAFPID-32002",
          "CSAFPID-32003",
          "CSAFPID-32004"
        ],
        "summary": "Fixed products."
      }
    ],
    "relationships": [
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <1.7.3 installed on CHARX SEC-3150",
          "product_id": "CSAFPID-31001"
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <1.7.3 installed on CHARX SEC-3100",
          "product_id": "CSAFPID-31002"
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11002"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <1.7.3 installed on CHARX SEC-3050",
          "product_id": "CSAFPID-31003"
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11003"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <1.7.3 installed on CHARX SEC-3000",
          "product_id": "CSAFPID-31004"
        },
        "product_reference": "CSAFPID-21001",
        "relates_to_product_reference": "CSAFPID-11004"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW 1.7.3 installed on CHARX SEC-3150",
          "product_id": "CSAFPID-32001"
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW 1.7.3 installed on CHARX SEC-3100",
          "product_id": "CSAFPID-32002"
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11002"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW 1.7.3 installed on CHARX SEC-3050",
          "product_id": "CSAFPID-32003"
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11003"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW 1.7.3 installed on CHARX SEC-3000",
          "product_id": "CSAFPID-32004"
        },
        "product_reference": "CSAFPID-22001",
        "relates_to_product_reference": "CSAFPID-11004"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <=1.6.5 installed on CHARX SEC-3150",
          "product_id": "CSAFPID-31005"
        },
        "product_reference": "CSAFPID-21002",
        "relates_to_product_reference": "CSAFPID-11001"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <=1.6.5 installed on CHARX SEC-3100",
          "product_id": "CSAFPID-31006"
        },
        "product_reference": "CSAFPID-21002",
        "relates_to_product_reference": "CSAFPID-11002"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <=1.6.5 installed on CHARX SEC-3050",
          "product_id": "CSAFPID-31007"
        },
        "product_reference": "CSAFPID-21002",
        "relates_to_product_reference": "CSAFPID-11003"
      },
      {
        "category": "installed_on",
        "full_product_name": {
          "name": "FW <=1.6.5 installed on CHARX SEC-3000",
          "product_id": "CSAFPID-31008"
        },
        "product_reference": "CSAFPID-21002",
        "relates_to_product_reference": "CSAFPID-11004"
      }
    ]
  },
  "vulnerabilities": [
    {
      "acknowledgments": [
        {
          "names": [
            "Jesson Soto Ventura",
            "Matthew Waddell"
          ],
          "organization": "ivision",
          "summary": "reporting."
        }
      ],
      "cve": "CVE-2025-24002",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An unauthenticated remote attacker can use MQTT messages to crash a service on charging stations complying with German Calibration Law, resulting in a temporary denial-of-service for these stations until they got restarted by the watchdog.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-31005",
          "CSAFPID-31006",
          "CSAFPID-31007",
          "CSAFPID-31008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "environmentalScore": 5.3,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 5.3,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31005",
            "CSAFPID-31006",
            "CSAFPID-31007",
            "CSAFPID-31008"
          ]
        }
      ],
      "title": "CVE-2025-24002"
    },
    {
      "acknowledgments": [
        {
          "names": [
            "Jesson Soto Ventura",
            "Matthew Waddell"
          ],
          "organization": "ivision",
          "summary": "reporting."
        }
      ],
      "cve": "CVE-2025-24003",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An unauthenticated remote attacker can use MQTT messages to trigger out-of-bounds writes in charging stations complying with German Calibration Law, resulting in a loss of integrity for only EichrechtAgents and potential denial-of-service for these stations.\n\n",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-31005",
          "CSAFPID-31006",
          "CSAFPID-31007",
          "CSAFPID-31008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "environmentalScore": 8.2,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 8.2,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31005",
            "CSAFPID-31006",
            "CSAFPID-31007",
            "CSAFPID-31008"
          ]
        }
      ],
      "title": "CVE-2025-24003"
    },
    {
      "acknowledgments": [
        {
          "names": [
            "Jesson Soto Ventura",
            "Matthew Waddell"
          ],
          "organization": "ivision",
          "summary": "reporting."
        }
      ],
      "cve": "CVE-2025-24004",
      "cwe": {
        "id": "CWE-120",
        "name": "Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.\n\n",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-31005",
          "CSAFPID-31006",
          "CSAFPID-31007",
          "CSAFPID-31008"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "environmentalScore": 5.2,
            "environmentalSeverity": "MEDIUM",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "temporalScore": 5.2,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31005",
            "CSAFPID-31006",
            "CSAFPID-31007",
            "CSAFPID-31008"
          ]
        }
      ],
      "title": "CVE-2025-24004"
    },
    {
      "acknowledgments": [
        {
          "names": [
            "Jesson Soto Ventura",
            "Matthew Waddell"
          ],
          "organization": "ivision",
          "summary": "reporting."
        }
      ],
      "cve": "CVE-2025-24005",
      "cwe": {
        "id": "CWE-20",
        "name": "Improper Input Validation"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A local attacker with a local user account can leverage a vulnerable script via SSH to escalate privileges to root due to improper input validation.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-32001",
          "CSAFPID-32002",
          "CSAFPID-32003",
          "CSAFPID-32004"
        ],
        "known_affected": [
          "CSAFPID-31001",
          "CSAFPID-31002",
          "CSAFPID-31003",
          "CSAFPID-31004"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
          "group_ids": [
            "CSAFGID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues..",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 7.8,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "temporalScore": 7.8,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31001",
            "CSAFPID-31002",
            "CSAFPID-31003",
            "CSAFPID-31004"
          ]
        }
      ],
      "title": "CVE-2025-24005"
    },
    {
      "acknowledgments": [
        {
          "names": [
            "Jesson Soto Ventura",
            "Matthew Waddell"
          ],
          "organization": "ivision",
          "summary": "reporting."
        }
      ],
      "cve": "CVE-2025-24006",
      "cwe": {
        "id": "CWE-269",
        "name": "Improper Privilege Management"
      },
      "notes": [
        {
          "category": "summary",
          "text": "A low privileged local attacker can leverage insecure permissions via SSH on the affected devices to escalate privileges to root.\n",
          "title": "Summary"
        }
      ],
      "product_status": {
        "fixed": [
          "CSAFPID-32001",
          "CSAFPID-32002",
          "CSAFPID-32003",
          "CSAFPID-32004"
        ],
        "known_affected": [
          "CSAFPID-31001",
          "CSAFPID-31002",
          "CSAFPID-31003",
          "CSAFPID-31004"
        ]
      },
      "remediations": [
        {
          "category": "mitigation",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
          "group_ids": [
            "CSAFGID-0001"
          ]
        },
        {
          "category": "vendor_fix",
          "date": "2025-06-03T10:00:00.000Z",
          "details": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues.",
          "group_ids": [
            "CSAFGID-0001"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "environmentalScore": 7.8,
            "environmentalSeverity": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "temporalScore": 7.8,
            "temporalSeverity": "HIGH",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-31001",
            "CSAFPID-31002",
            "CSAFPID-31003",
            "CSAFPID-31004"
          ]
        }
      ],
      "title": "CVE-2025-24006"
    }
  ]
}